Healthcare-associated infection impact with bioaerosol treatment and COVID-19 mitigation measures

Open AccessPublished:July 21, 2021DOI:https://doi.org/10.1016/j.jhin.2021.07.006

      Summary

      Background

      The real-world impact of breathing zone air purification and coronavirus disease 2019 (COVID-19) mitigation measures on healthcare-associated infections is not well documented. Engineering solutions to treat airborne transmission of disease may yield results in controlled test chambers or single rooms, but have not been reported on hospital-wide applications, and the impact of COVID-19 mitigation measures on healthcare-associated infection rates is unknown.

      Aim

      To determine the impact of hospital-wide bioaerosol treatment and COVID-19 mitigation measures on clinical outcomes.

      Methods

      The impact of the step-wise addition of air disinfection technology and COVID-19 mitigation measures to standard multi-modal infection control on particle counts, viral and bacterial bioburden, and healthcare-associated infection rates was investigated in a 124-bed hospital (>100,000 patient-days over 30 months).

      Findings and conclusion

      The addition of air disinfection technology and COVID-19 mitigation measures reduced airborne ultrafine particles, altered hospital bioburden, and reduced healthcare-associated infections from 11.9 to 6.6 (per 1000 patient-days) and from 6.6 to 1.0 (per 1000 patient-days), respectively (P<0.0001, R2=0.86). No single technology, tool or procedure will eliminate healthcare-associated infections, but the addition of a ubiquitous facility-wide engineering solution at limited expense and with no alteration to patient, visitor or staff traffic or workflow patterns reduced infections by 45%. A similar impact was documented with the addition of comprehensive, restrictive, and labour- and material-intensive COVID-19 mitigation measures. To the authors' knowledge, this is the first direct comparison between traditional infection control, an engineering solution and COVID-19 mitigation measures.

      Keywords

      Introduction

      Bioaerosols that carry bacteria, viruses and fungi serve as transmission vehicles for diverse infections, including influenza viruses, severe acute respiratory syndrome viruses, and the novel human coronavirus (SARS-CoV-2). Sneezing, coughing, speaking and breathing release and disperse droplets and virus particles [
      • Bischoff W.E.
      • Swett K.
      • Leng I.
      • Peters T.R.
      Exposure to influenza virus aerosols during routine patient care.
      ,
      • Fabian P.
      • McDevitt J.J.
      • DeHaan W.H.
      • Fung R.O.
      • Cowling B.J.
      • Chan K.H.
      • et al.
      Influenza virus in human exhaled breath: an observational study.
      ]. The clinical consequences of bioaerosols involve complex physical and biological factors, and disinfecting bioaerosols is difficult in any indoor air environment.
      Cough- and sneeze-generating gas clouds with pathogen-bearing droplets can travel up to 8 m, and, once desiccated, the residue or droplet nuclei may stay suspended for hours [
      • Bourouiba L.
      Turbulent gas clouds and respiratory pathogen emissions: potential implications for reducing transmission of COVID-19.
      ]. Some of the smallest particles (such as viruses <30 nm in diameter) can invade a room rapidly and may be the most infectious [
      • Morawska L.
      • Johnson G.R.
      • Ristovski Z.D.
      • Hargreaves M.
      • Mengersen K.
      • Corbett S.
      • et al.
      Size distribution and sites of origin of droplets expelled from the human respiratory tract during expiratory activities.
      ,
      • Fennelly K.P.
      Particle sizes of infectious aerosols: implications for infection control.
      ]. Even large particles (droplets >100 μm) can be resuspended and aerosolized, and may behave like small aerosols due to the local environment [
      • Rezapoor M.
      • Alvand A.
      • Jacek E.
      • Paziuk T.
      • Maltenfort M.G.
      • Parvizi J.
      Operating room traffic increases aerosolized particles and compromises the air quality: a simulated study.
      ,
      • Bhattacharya A.
      • Pantelic J.
      • Ghahramani A.
      • Mousavi E.S.
      Three-dimensional analysis of the effect of human movement on indoor airflow patterns.
      ]. Aerosols and droplets are subject to a person's thermal plume, air currents produced by human traffic, door movements, electrostatic forces, Brownian motion and convective flows [
      • Tang J.W.
      • Bahnfleth W.P.
      • Bluyssen P.M.
      • Buonanno G.
      • Jimenez J.L.
      • Kumitski J.
      • et al.
      Dismantling myths on the airborne transmission of severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2).
      ,
      • Li C.
      • Wang H.
      • Yu C.W.
      • Xie D.
      Diffusion characteristics of the industrial submicron particle under Brownian motion and turbulent diffusion.
      ,
      • Wagner J.A.
      • Greeley D.G.
      • Gormley T.C.
      • Markel T.A.
      Comparison of operating room air distribution systems using the environmental quality indicator method of dynamic simulated surgical procedures.
      ,
      • Agodi A.
      • Auxilia F.
      • Barchitta M.
      • Cristina M.L.
      • D'Alessandro D.
      • Mura I.
      • et al.
      Operating theatre ventilation systems and microbial air contamination in total joint replacement surgery: results of the GISIO-ISChIA study.
      ]. The constant and turbulent factors within a typical hospital increase broader dissemination, and extend the settling time of these disease-carrying pathogens [
      • Birgand G.
      • Peiffer-Smadja N.
      • Fournier S.
      • Kerneis S.
      • Lescure F.X.
      • Lucet J.C.
      Assessment of air contamination by SARS-CoV-2 in hospital settings.
      ].
      There is now evidence to warrant engineering controls that target airborne transmission as part of an overall strategy to limit indoor infectious risk [
      • Morawska L.
      • Tang J.W.
      • Bahnfleth W.
      • Bluyssen P.M.
      • Boerstra A.
      • Buonanno G.
      • et al.
      How can airborne transmission of COVID-19 indoors be minimised?.
      ]. Components of these strategies include air disinfection, ventilation, enhanced particle filtration and avoidance of recirculation. Traditional infection control strategies such as education, handwashing, surface cleaning and isolation measures with personal protective equipment (PPE) were primarily developed for large droplet and surface contamination. Such strategies have limited ability to combat airborne pathogens, especially those suspended continuously within 0.3-m radius of a nose and mouth, commonly described as the ‘breathing zone’. Given the human and environmental factors that constantly move aerosols and resuspend droplets, the concept of clearing a room of all suspended or airborne pathogens is not as simple as increasing air flow and installing a finer filter [
      • Agodi A.
      • Auxilia F.
      • Barchitta M.
      • Cristina M.L.
      • D'Alessandro D.
      • Mura I.
      • et al.
      Operating theatre ventilation systems and microbial air contamination in total joint replacement surgery: results of the GISIO-ISChIA study.
      ].
      Current technologies that help clean a ducted air stream include high-efficiency particulate air (HEPA) filtration, heating ventilation and air-conditioning modifications, ultraviolet (UV) radiation, and various intraduct oxidizing or ionizing technologies [
      • Morawska L.
      • Tang J.W.
      • Bahnfleth W.
      • Bluyssen P.M.
      • Boerstra A.
      • Buonanno G.
      • et al.
      How can airborne transmission of COVID-19 indoors be minimised?.
      ]. Benefits attributed to these technologies are often cited from tightly controlled experiments within test chambers, but these are not real-world settings. Each of these technologies may provide benefit within environmental chambers, but few have the capacity to continuously counter the numerous and constant infectious and environmental perturbations of a real-world setting. Ideal air disinfection would be easily applied to all areas so that all breathing zone air would be treated, and would result in reduced particulate pollution, reduced pathogen contamination, reduced disease transmission and, finally, a reduction in real-world clinical infections.
      The ACTIVE Particle Control (APC) system (SecureAire, LLC, Dunedin, FL, USA) has been shown to reduce fine and ultrafine airborne particles and pathogens in live operating rooms, reduce bacterial contamination in active hospital compounding pharmacies, and rapidly inactivate or kill the highly resistant anthrax surrogate (Bacillus subtilis) [
      • Ereth M.H.
      • Hess D.H.
      • Driscoll A.
      • Hernandez M.
      • Stamatatos F.
      Particle control reduces fine and ultrafine particles greater than HEPA filtration in live operating rooms and kills biologic warfare surrogate.
      ,
      SecureAire, LLC
      ACTIVE Particle Control technology and USP 800 pharmaceutical compounding.
      ]. This novel technology works by local electromagnetic field manipulation [controlled ionization, enhanced polarization and controlled particle transport (direction and velocity)]. These forces condition the microparticles (microscopic particles 1–1000 μm) and pathogens within a space, so they continuously initiate millions of particle–particle (ionization) and particle–molecular (polarization) collisions. These collisions lead to immediate and permanent ionically driven aggregations of fine and ultrafine particles and pathogens into larger particles. With the larger aggregates attaining a critical mass, their transport becomes controlled by air flow and they can be carried by air currents to the particle collector (Figure 1).
      Figure 1
      Figure 1Mechanism of action of the ACTIVE Particle Control system. Particulate pollutants, viruses, bacteria and allergens enter the conditioning phase and exit with a net-neutral charge. The technology-accelerated collisions result in particle agglomeration. The larger coagulated particles and their increased mass are subject to air currents that deliver the same to the collector media. Once collected, the highly defined high voltage field induces oxidative stress killing or inactivates any biological material.
      This study aimed to determine the impact of adding a hospital-wide APC system and coronavirus disease (COVID-19) mitigation measures to a multi-modal infection control strategy on particle and pathogen counts, respiratory viral illnesses and healthcare-associated infections (HAIs).

      Methods

      Facility

      This work was conducted at St. Mary's Hospital for Children in Bayside, Queens, NY, USA St. Mary's Hospital is a 124-bed paediatric post-acute care facility that provides for children with special healthcare needs and medically complex conditions. Multi-disciplinary teams of paediatric specialists provide care at St. Mary's Hospital.

      Standard infection control programme

      The comprehensive infection control programme of St. Mary's Hospital operates daily with ongoing and concurrent multi-modal processes to optimize the safety of patients, families, personnel, visitors and the environment. The programme reports process and outcome surveillance monthly. Key components of the standard programme include handwashing promotions and signage, infection monitoring, facility antibiogram surveillance, antibiotic stewardship, transmission-based precaution modalities, PPE usage, and scheduled cleaning and disinfection procedures. Automated hand sanitizing surveillance using Bluetooth technology captures the compliance of hand hygiene upon entry or exit from the residents' rooms, and from bed-to-bed encounters, and documents the technique and duration of hand hygiene for each staff member. Terminal cleaning of all surfaces with disinfectant is carried out upon patient room changes, and portable UV disinfection is conducted in every patient room upon patient discharge and every 5–6 weeks for routine resident room cleaning and in general common areas (Figure 2).
      Figure 2
      Figure 2Progressive infection control methods. Standard infection control procedures were in place in 2018. ACTIVE Particle Control technology was implemented in late February 2019, and comprehensive coronavirus disease 2019 (COVID-19) restriction and mitigation measures were implemented in late February 2020.

      APC intervention

      The APC system was added to the standard infection control programme in February 2019. Three commercial-sized roof-top components were added to each of the air-handling units bringing the solution to all common areas, all patient rooms, and all staff and treatment rooms. The APC system has been maintained and in operation since installation. The only hospital/patient care area that is not part of this continuous air-disinfection treatment was a single newly remodelled area (Figure 3). No data or results from this patient care unit were included in this study.
      Figure 3
      Figure 3Roof-top placement of ACTIVE Particle Control units. ACTIVE Particle Control devices were placed within roof-top air-handling units. The entire complex is covered, with the exception of one patient unit (identified in orange).

      COVID-19 mitigation measures

      Comprehensive COVID-19 mitigation measures were deployed in late February 2020 and included restricted visitation, screening upon entry, restrictions on volunteers and students, discontinued outpatient services, and a facility-wide comprehensive hand hygiene programme. Use of an N95 respirator mask, or face mask and visor or shield, during aerosol-generating procedures, and universal masking at other times were required (Figure 2).

      Measurements and outcomes

      Infection control personnel conducted air quality testing for ultrafine particles (>0.35 μm) and completed air sampling for bacteria and fungi before and after installation of the APC system. Particle counts were determined using a laser-based particle counter (National Institute of Standards and Technology specifications for measuring particles >0.35 μm and >2.5 μm). Engineering control records including ventilation filter rating, humidity and temperature were documented by building engineers. Data sources included the electronic medical record, laboratory result record and hospital census records. Bacterial, fungal, respiratory viral pathogens, total pathogens and HAIs from all sources were documented continuously by infection control personnel. The predominant infectious aetiology and species isolates were documented, and total infections and infections per 1000 patient-days were determined. Next, comparisons were made between the results before and after the addition of the APC system, and after the addition of COVID-19 mitigation measures (Table I).
      Table IHospital characteristics and healthcare-associated infections
      Standard IC

      Mar–Dec 2018
      Standard IC

      +

      APC system

      Mar–Dec 2019
      Standard IC

      +

      APC system

      +

      COVID-19 mitigation

      Mar–Dec 2020
      Hospital characteristics

      Months101010
      Patient-days31,21336,30937,377
      Filter MERV ratingMERV-8 Pre

      MERV-15 Post
      MERV-8 Pre

      MERV-15 Post
      MERV-8 Pre

      MERV-15 Post
      Average indoor relative humidity (%)38–4238–4238–42
      Average indoor temperature (◦F)70–7270–7270–72
      Most common bacterial culture resultsPeudomonas

      aeruginosa
      Pseudomonas aeruginosaPseudomonas

      aeruginosa
      Most common respiratory viral pathogensEnterovirus

      Rhinovirus
      Enterovirus

      Rhinovirus
      Enterovirus

      Rhinovirus
      Healthcare-associated infections

      (/1000 patient-days)
      Mean (95% CI)11.91

      (10.67–13.15)
      6.71

      (5.47–7.95)
      1.03

      (0.00–2.27)
      Median (IQR)11.55

      (11.00–13.00)
      6.00

      (5.10–8.10)
      0.95

      (0.80–1.30)
      Range9.10–14.601.60–11.600.30–2.10
      Analysis of variance model
      Pairwise Bonferroni multiple comparisons significance level would be compared with 0.017 (rather than 0.05).


      Mean difference (95% CI)
      IC + APC − IC−5.20

      (−7.32 to −3.08)
      IC + APC + COVID − IC−10.88

      (−13.00 to −8.76)
      IC + APC + COVID − IC + APC−5.68

      (−7.80 to −3.56)
      P-valueP<0.0001P<0.0001
      Overall P-valueP<0.0001
      Model R2 value0.86
      MERV, minimum efficiency reporting value; CI, confidence interval; IQR, interquartile range; IC, infection control; APC, ACTIVE Particle Control; COVID-19, coronavirus disease 2019.
      a Pairwise Bonferroni multiple comparisons significance level would be compared with 0.017 (rather than 0.05).

      Statistical analysis

      The mean, median and interquartile ranges were determined for particle counts, bacterial and fungal cultures, respiratory viral illness and HAIs. Comparisons were made between laboratory and clinical outcomes with the standard infection control programme, after the addition of the APC system, and after the addition of COVID-19 mitigation measures. Comparisons between these three groups were conducted using t-tests, analysis of variance, pairwise Bonferroni multiple comparisons and R2 analyses. P<0.05 was considered to indicate statistical significance (<0.017 for Bonferroni correction).

      Results

      Patient population and characteristics

      The study was conducted over 30 months with over 100,000 patient-days. The average monthly census and general diagnoses on admission did not vary significantly between any of the intervention groups. Patient, facility and microbial characteristics are summarized in Table I.

      Study interval and timeline

      Three consecutive years were studied. Outcomes from January and February in 2019 and 2020 would have reflected mixed or partially applied APC and COVID-19 procedures, and were thus excluded. Calendar months were also chosen in order to eliminate the possible impact of seasonal variation in allergens and influenza illness (Table I and Figure 2). Regular infection control procedure monitoring for 2018, 2019 and 2020 revealed very high and comparable rates of influenza immunization, handwashing, surface disinfection, droplet and aerosol isolation, and education measures.

      Particle counts and hospital bioburden

      Mean airborne particle counts (>0.35 μm/ft3) were reduced by 12–55% (mean 29%) after installation of the APC system (P<0.01) (Figure S1, see online supplementary material). Following installation of the APC system, few-to-no Gram-negative species were cultured, reflecting a shift in the facility-wide bioburden. None of the fungal isolates were pathogenic after installation of the APC system, as all were environmental species commonly found in households and garden areas. In the first 3 months after installation of the APC system, the respiratory viral illness rate was reduced by >90% (P< 0.001). This varied throughout the 10-month study period and, while the mean respiratory viral illness rate did increase somewhat, it remained lower than in previous years and thus was reduced first by the APC system and second by the COVID-19 mitigation measures (Figure S2, see online supplementary material).

      Healthcare-associated infections

      Following implementation of the APC system, HAIs were reduced by 45% from an average of 11.9/1,000 patient-days for the standard infection control period to an average of 6.6/1000 patient-days (P<0.0001). The implementation of comprehensive COVID-19 mitigation measures in late February 2020 reduced all HAIs by another 47% to 1.0/1000 patient-days (P<0.0001) (Table I and Figure 4). The model analysis revealed an R2 value of 0.86 (approximately 86% of the variation in the mean infection rates was accounted for by each mitigation measure). The COVID-19 mitigation measures, including community restrictions, were associated with a decline in all respiratory viral illnesses by another 72% beyond the significant impact of the APC system. The addition of the APC system was also associated with a 63% reduction in wound infections, which did not decline further with COVID-19 mitigation measures. Implementing air disinfection technology was associated with an 89% reduction in tracheitis, but did not improve further with COVID-19 mitigation measures. The incidence of Clostridoides difficile infections did not change after the addition of the APC system, but did decline 90% after the implementation of COVID-19 mitigation measures.
      Figure 4
      Figure 4Healthcare-associated infection rates. Baseline mean healthcare-associated infection (HAI) rate with standard infection control (IC) was 11.9/1000 patient-days; this reduced to 6.7/1000 patient-days after implementation of the ACTIVE Particle Control (APC) system (P<0.0001), and 1.0/1000 patient-days after implementation of comprehensive COVID-19 restriction and mitigation measures (P<0.0001). Analysis of variance (with and without Bonferroni multiple comparisons): P<0.0001. With each additional infection prevention measure, 86% of the variation in HAI rate was due to the mitigation procedure (R2=0.86).

      Discussion

      Application of the APC system as an adjunct air disinfection method was associated with significantly reduced HAIs, bacterial and fungal contamination, respiratory viral pathogens and airborne particles. Further reductions in respiratory and total viral pathogens and HAIs were seen with the addition of comprehensive COVID-19 restriction and mitigation measures.

      APC system effectively clears airborne particles and pathogens

      The smallest of airborne pathogens, which are likely the most pathogenic, are the most difficult to capture by traditional filtering methods. APC technology treats and captures all particles equally, including volatile organic compounds, viruses, spores, bacteria, smoke, pollen and other aerosolized allergens [
      • Ereth M.H.
      • Hess D.H.
      • Driscoll A.
      • Hernandez M.
      • Stamatatos F.
      Particle control reduces fine and ultrafine particles greater than HEPA filtration in live operating rooms and kills biologic warfare surrogate.
      ]. Unlike filters, this solution is agnostic to bioaerosol character or size, and is therefore effective on all particles and pathogens (Figure 1). The technology operates continuously and responds rapidly to challenges introduced to a ventilated space by human activity. The behaviour of all particles (pollutants, aerosolized or airborne viruses and bacteria, pollen, etc.) is guided principally by physical laws and, to a lesser degree, by chemical and biological influences. It is the mass and spatial characteristics of these ultrafine particles (including viruses and bacteria) that keep them suspended for long periods of time, allowing for wide dispersion and diffusion. The APC system imparts both positive and negative charges, in a controlled manner utilizing Gauss's Law (Maxwell's first equation), on individual particles and pathogens. The technology hardware, firmware and software methodically control the electronic forces applied to fine and ultrafine particles.
      The mechanism of the clinical impact of the APC system is multi-fold. First, by significantly reducing the resident time of pathogens within a hospital room or common area, the chance of adequate inoculum to infect a subject is significantly reduced. Second, pathogens and large droplets that have previously settled on surfaces and are resuspended by human activity become susceptible to APC treatment. Lastly, the technology responds rapidly and effectively to new pathogen challenges generated by coughs, sneezes or other human activity.

      Limitations of methods and results

      The single greatest limitation of this study is also its greatest strength. It was conducted in a real-world live hospital with many uncontrolled variables. As such, it is difficult to demonstrate a direct cause and effect between the intervention and a specific outcome for a specific patient. Conversely, the greatest strength of this work is that it was conducted in a live paediatric facility with a diverse patient population with varied co-morbidities, and with patients, clinicians, caregivers and family coming and going 24/7. All standard infection control procedures, processes and personnel remained consistent throughout the study, as did the patient load and general clinical characteristics of the patient population. With the COVID-19 pandemic, additional comprehensive restrictions and mitigation procedures were added. Another concern may be that airborne particles and pathogens were sampled periodically but not continuously. Viral cultures were collected from symptomatic patients, and laser-based particle counters that are an excellent surrogate for pathogen load, especially when measured at 0.4 μm, were used [
      • Raval J.S.
      • Koch E.
      • Donnenberg A.D.
      Real-time monitoring of non-viable airborne particles correlates with airborne colonies and represents an acceptable surrogate for daily assessment of cell-processing cleanroom performance.
      ].
      Critics may insist that such a result cannot be attributed to a single intervention. There are numerous examples of therapies or, in this case, an engineering solution providing synergistic benefits. The APC system was added with the express purpose of providing hospital-wide air disinfection. The study was conducted entirely by internal personnel, internal sample and laboratory culture procedures, internal data and analysis, and without outside funding or influence. The results speak for themselves in that the interventions overcame all confounding patient and facility variables.

      Aerosolized pathogens generated by normal breathing may be the most dangerous

      Healthy and influenza-infected subjects exhale up to 10,000 particles per litre during tidal breathing, with the majority being <0.3 μm in diameter [
      WHO
      Modes of transmission of virus causing COVID-19: implications for IPC precaution recommendations.
      ,
      CDC
      Interim infection prevention and control recommendations for patients with suspected or confirmed conronavirus disease 2019 (COVID-19 in healthcare settings.
      ,
      • Edwards D.A.
      • Man J.C.
      • Brand P.
      • Kastra J.P.
      • Sommerer K.
      • Stone H.A.
      • et al.
      Inhaling to mitigate exhaled bioaerosols.
      ]. Normal tidal volume exhalations, sneezes and coughs contain short-range semi-ballistic emissions that disperse quickly [
      • Bourouiba L.
      • Dehandschoewercker E.
      • Bush J.W.M.
      Violent expiratory events: on coughing and sneezing.
      ]. Most exhaled pathogens are carried in fine particles (0.7–1.0 μm) [
      • Bake B.
      • Larsson P.
      • Ljungkvist G.
      • Ljungström E.
      • Olin A.C.
      Exhaled particles and small airways.
      ]. In one study, 90% of influenza viral RNA was found in exhaled particles <1.0 μm, with those same fine particles carrying eight to nine times more viral copies compared with larger droplets. Lastly, pathogens and aerosols can remain suspended in the air for long periods of time [
      • van Doremalen N.
      • Bushmaker T.
      • Morris D.H.
      • Holbrook M.G.
      • Gamble A.
      • Williamson B.N.
      • et al.
      Aerosol and surface stability of SARS-CoV-2 as compared with SARS-CoV-1.
      ], with the smallest pathogens remaining resident for the longest [
      • Li C.
      • Wang H.
      • Yu C.W.
      • Xie D.
      Diffusion characteristics of the industrial submicron particle under Brownian motion and turbulent diffusion.
      ,
      • Lindsley W.G.
      • King W.P.
      • Thewlis R.E.
      • Reynolds J.S.
      • Panday K.
      • Cao G.
      • et al.
      Dispersion and exposure to a cough-generated aerosol in a simulated medical examination room.
      ].

      Traditional air purification technology

      Traditional air filtration is effective at removing large particulates such as pollen, mould and animal dander from the air, yet there are limitations. Viable bioaerosols such as bacteria, viruses and fungi can be demonstrated on filter media for up to 10 h after aerosolization. In less than 48 h after installation, 30% of filter media from commercial air-handling units have been contaminated with viable picornavirus, coronaviruses and parainfluenza viruses [
      • Myatt T.A.
      • Johnston S.L.
      • Zuo Z.
      • Wand M.
      • Kebadze T.
      • Rudnick S.
      • et al.
      Detection of airborne rhinovirus and its relation to outdoor air supply in office environments.
      ].
      Air purification technology, such as HEPA, bipolar ionizers, photo electrochemical oxidation and UV light, can be beneficial but has significant limitations. HEPA filters effectively remove contaminants once presented to the filter matrix. However, as discussed previously, moving ultrafine particles and pathogens that are indefinitely suspended to the filter remains a limitation. Viruses are approximately 100 times smaller than bacteria, and typically range from 0.004 to 0.1 μm in size. This means that even the most efficient air filters would struggle to purge a virus from the air. It has also been demonstrated that mengovirus can pass through filters commonly used in air-handling units, and remains infectious upstream and downstream of the filter for long periods after aerosolization [
      • Bandaly V.
      • Joubert A.
      • Le Cann P.
      • Andres Y.
      The fate of mengovirus on fiberglass filter of air handling units.
      ]. Many bipolar air purifiers use uncontrolled ionization to bind particles, causing pathogens to stick to surfaces within a given space. Recently, the generation of noxious chemical by-products and ozone from bipolar ionization devices has been documented, and the technology has been criticized [
      • Zeng Y
      • Manwatkar P
      • Laguerre A
      • et al.
      Evaluating a commercially available in-duct bipolar ionization device for pollutant removal and potential byproduct formation.
      ,
      • Zaatari M.
      • Harmon M.
      Open letter to address the use of electronic air cleaning equipment in buildings. medium.com.
      ]. The APC system distinguishes itself from bipolar ionization in that it does not create an electronic corona, nor does it generate chemical reactions or ozone [
      • Intertek
      SecureAire LLC ozone test report.
      ]. The photo electrochemical oxidation solution can react with some pollutants to generate dangerous by-products such as formaldehyde, nitrogen dioxide and carbon monoxide. Disinfection with UV light is time- and intensity-dependent, and is highly effective on flat surfaces yet does not kill airborne pathogens, and the benefits of UV disinfection only persist until human traffic re-enters and contaminates the treated space [
      • Ong S.W.X.
      • Tan Y.K.
      • Chia P.Y.
      • Lee T.H.
      • Ng O.T.
      • Wong M.S.Y.
      • et al.
      Air, surface environmental, and personal protective equipment contamination by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) from a symptomatic patient.
      ].
      Particle size is the most important determinant of aerosol behaviour. Particles ≤5 μm in size can remain airborne indefinitely under most indoor conditions [
      • Li C.
      • Wang H.
      • Yu C.W.
      • Xie D.
      Diffusion characteristics of the industrial submicron particle under Brownian motion and turbulent diffusion.
      ,
      • Wells W.F.
      Aerodynamics of droplet nuclei. Airborne contagion and air hygiene: an ecological study of droplet infections.
      ,
      • Brown J.H.
      • Cook K.M.
      • Ney F.G.
      • Hatch T.
      Influence of particle size upon the retention of particulate matter in the human lung.
      ]. Immediately respirable aerosols from exhaled breath and coughs are generally fine (<2.5 μm) or ultrafine (<0.1 μm), and appear to carry the largest inoculum of viruses; as such, they are the most infectious [
      • Scheuch G.
      Breathing is enough: for the spread of influenza virus and SARS-CoV-2 by breathing only.
      ].

      Healthcare-associated infections

      HAIs are the most common complication of health care and are one of the top 10 leading causes of death [
      • Agency for Healthcare Research and Quality
      Healthcare-associated infections.
      ]. Controlling airborne transmission of infection is not simple or easy. Antiseptic techniques, wearing PPE and infection prevention procedures are critical. Also critical is deploying engineering solutions that are proven to reduce patient complications [
      • van Rijn C.
      • Somsen G.A.
      • Hofstra L.
      • Dahhan G.
      • Gem R.A.
      • Kooij S.
      • et al.
      Reducing aerosol transmission of SARS-CoV-2 in hospital elevators.
      ]. Both the APC system and the COVID-19 mitigation measures resulted in similar reductions in the HAI rate. The first solution required a single capital outlay and runs continuously, and never interrupts staff work flow or inconveniences patients or family members. The second solution is time-, equipment-, material- and labour-intensive, and causes significant interruptions to staff work flow.

      Engineering solutions applied across all spaces

      There is now strong evidence to warrant engineering solutions that target immediately respirable particles (viral laden aerosols) in the 0.7–1.0-μm range [
      • Tang J.W.
      • Bahnfleth W.P.
      • Bluyssen P.M.
      • Buonanno G.
      • Jimenez J.L.
      • Kumitski J.
      • et al.
      Dismantling myths on the airborne transmission of severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2).
      ]. This is even more important as the evidence base for the 1–2-m rule of spatial separation is inconclusive, and it is known that aerosols can travel horizontally for up to 9 m [
      • Bahl P.
      • Doolan C.
      • de Silva C.
      • Chughtai A.A.
      • Bourouiba L.
      • MacIntyre C.R.
      Airborne or droplet precautions for health workers treating COVID-19?.
      ,
      • Jones N.R.
      • Qureshi Z.U.
      • Temple R.J.
      • Larwood J.P.J.
      • Greenhalgh T.
      • Bourouiba L.
      Two metres or one: what is the evidence for physical distancing in COVID-19?.
      ,
      • Bazant M.Z.
      • Bush J.W.M.
      A guideline to limit indoor airborne transmission of COVID-19.
      ].
      Effective engineering solutions must harness the laws of physics to enable clearance of particle pollutants and pathogens from the ventilated space. The repeated assumption is that all airborne pathogens, regardless of size, behave the same and are susceptible to air currents. The incorrect assumption is that air flow alone can transport pathogens to the filter or device, where they are completely cleared from the air stream. These assumptions counter the laws of physics which dictate that ultrafine particles are more susceptible to electrostatic forces than gravity or air currents [
      • Li C.
      • Wang H.
      • Yu C.W.
      • Xie D.
      Diffusion characteristics of the industrial submicron particle under Brownian motion and turbulent diffusion.
      ]. Specialized ventilation, such as positive and negative pressurized rooms and high air exchanges per hour, may help to prevent the spread of disease, but this is expensive to install, has high energy costs, and does not fully address the human traffic factor in aerosol dispersion [
      • Santarpia J.L.
      • Rivera D.N.
      • Herrera V.L.
      • Morwitzer M.J.
      • Creager H.M.
      • Santarpia G.W.
      • et al.
      Aerosol and surface contamination of SARS-CoV-2 observed in quarantine and isolation care.
      ].

      Airborne transmission of non-airborne infections?

      Over the past 18 months, the transmission of disease has been actively studied, and there is greater awareness of the complexity of coughs and sneezes and the aerosols they produce. Understanding of the impact of human activities on indoor air currents, resuspension of settled droplets, unintended consequences of air currents in operating rooms, and broader concepts of pathogen migration has improved [
      • Rezapoor M.
      • Alvand A.
      • Jacek E.
      • Paziuk T.
      • Maltenfort M.G.
      • Parvizi J.
      Operating room traffic increases aerosolized particles and compromises the air quality: a simulated study.
      ,
      • Bhattacharya A.
      • Pantelic J.
      • Ghahramani A.
      • Mousavi E.S.
      Three-dimensional analysis of the effect of human movement on indoor airflow patterns.
      ,
      • Agodi A.
      • Auxilia F.
      • Barchitta M.
      • Cristina M.L.
      • D'Alessandro D.
      • Mura I.
      • et al.
      Operating theatre ventilation systems and microbial air contamination in total joint replacement surgery: results of the GISIO-ISChIA study.
      ].
      However, little is actually known about the relative contribution of disease transmission by contact, fomite, droplet or aerosol routes [
      • Leung N.H.L.
      Transmissibility and transmission of respiratory viruses.
      ]. The work presented here found that the APC system was associated with reductions in HAIs, wound infection, tracheitis and respiratory viral infections. Can air disinfection technology impact contact, fomite and droplet routes of disease transmission? Real-world evidence and three-dimensional modelling have demonstrated that air currents clearly alter dispersal of bacteria in operating rooms [
      • Rezapoor M.
      • Alvand A.
      • Jacek E.
      • Paziuk T.
      • Maltenfort M.G.
      • Parvizi J.
      Operating room traffic increases aerosolized particles and compromises the air quality: a simulated study.
      ,
      • Bhattacharya A.
      • Pantelic J.
      • Ghahramani A.
      • Mousavi E.S.
      Three-dimensional analysis of the effect of human movement on indoor airflow patterns.
      ,
      • Agodi A.
      • Auxilia F.
      • Barchitta M.
      • Cristina M.L.
      • D'Alessandro D.
      • Mura I.
      • et al.
      Operating theatre ventilation systems and microbial air contamination in total joint replacement surgery: results of the GISIO-ISChIA study.
      ]. Non-respiratory fomites in virally infected animals are readily aerosolized and airborne [
      • Asadi S.
      • Gaaloul Ben Hnia N.
      • Barre R.S.
      • Wexler A.S.
      • Ristenpart W.D.
      • Bouvier N.M.
      Influenza A virus is transmissible via aerosolized fomites.
      ]. Also, genetically traced and aerosolized Escherichia coli has been demonstrated in adjacent homes, demonstrating airborne transmission between built environments [
      • Li Z.
      • Wang H.
      • Zheng W.
      • Li Z.
      • Wang H.
      • Zheng W.
      • et al.
      A tracing method of airborne bacteria transmission across built environments.
      ]. Certainly, some human activities and/or engineering solutions may impart airborne transmissibility to traditionally non-airborne diseases, but what activity, to what degree, and what is the clinical outcome? Given this, it is certainly possible that a treatment targeting airborne disease could impact non-airborne disease. The question is simple, but the answers are complex, elusive and warrant further investigation.
      In conclusion, in a real-world hospital setting with over 100,000 patient-days over 30 months, there was a significant reduction in HAIs (including respiratory viral pathogens) when an engineering solution (APC system) was added to the standard infection control procedures. Even further reductions were achieved by comprehensive COVID-19 mitigation measures. Effectively disinfecting all breathing zone air may be especially helpful in reducing airborne disease transmission and acquired infections in hospitals or other institutional settings.

      Author contributions

      Dr. Simpser, Ms. Mathew and Ms. Fine were responsible for infection control policy development and supervision. Ms. Fine was responsible for implementation of infection control policies, staff education, surveillance, and infection control procedures and processes. She was also responsible for sample collection/coordination and data collection and analysis/visualization. Ms Fine and Mr. Stamatatos assisted with particle count methods and manuscript preparation. Mr. Hess provided technical guidance, data review and manuscript preparation. Dr. Ereth was responsible for additional data visualization and writing the manuscript.

      Acknowledgements

      The authors wish to thank Ms. Kimberly Sankey for assistance with manuscript preparation, Mr. William Scott Harmsen for statistical analysis, and Dr. William L. Lanier for review and guidance.

      Conflict of interest statement

      Dr. Ereth is Chief Medical Officer of, and an investor in, SecureAire, Inc. Mr. Stamatatos is Chief Executive Officer of, and an investor in, SecureAire, Inc. Mr. Hess is Chief Technical Officer of, and an investor in, SecureAire, Inc. Dr. Simpser, Ms. Fine and Ms. Mathew report no conflicts of interest.

      Funding sources

      All funding for this work was provided by St. Mary's Hospital for Children . The entire cost of purchase, installation and service of the APC system, all laboratory and personnel costs, and the cost of data collection and analysis was funded by St. Mary's Hospital for Children. The particle counter and graphic assistance were provided by SecureAire, Inc.

      Appendix ASupplementary data

      The following are the Supplementary data to this article:
      • Figure S1

        Representative mean ultrafine particle counts. Mean particle counts (>0.35 microns/ft3) before and after the implementation of the ACTIVE Particle Control system in three representative locations were reduced by 12–55% (mean 29%) (P<0.01).

      • Figure S2

        Total and respiratory viral pathogens. Total and respiratory viral pathogen bioburden was significantly reduced with addition of the ACTIVE Particle Control (APC) system and COVID-19 mitigation measures to the standard infection control (IC) procedures and protocols (P<0.01).

      References

        • Bischoff W.E.
        • Swett K.
        • Leng I.
        • Peters T.R.
        Exposure to influenza virus aerosols during routine patient care.
        J Infect Dis. 2013; 207: 1037-1046
        • Fabian P.
        • McDevitt J.J.
        • DeHaan W.H.
        • Fung R.O.
        • Cowling B.J.
        • Chan K.H.
        • et al.
        Influenza virus in human exhaled breath: an observational study.
        PLoS One. 2008; 3e2691
        • Bourouiba L.
        Turbulent gas clouds and respiratory pathogen emissions: potential implications for reducing transmission of COVID-19.
        JAMA. 2020; 323: 1837-1838
        • Morawska L.
        • Johnson G.R.
        • Ristovski Z.D.
        • Hargreaves M.
        • Mengersen K.
        • Corbett S.
        • et al.
        Size distribution and sites of origin of droplets expelled from the human respiratory tract during expiratory activities.
        J Aerosol Sci. 2009; 40: 256-269
        • Fennelly K.P.
        Particle sizes of infectious aerosols: implications for infection control.
        Lancet Respir Med. 2020; 8: 914-924
        • Rezapoor M.
        • Alvand A.
        • Jacek E.
        • Paziuk T.
        • Maltenfort M.G.
        • Parvizi J.
        Operating room traffic increases aerosolized particles and compromises the air quality: a simulated study.
        J Arthroplasty. 2018; 33: 851-855
        • Bhattacharya A.
        • Pantelic J.
        • Ghahramani A.
        • Mousavi E.S.
        Three-dimensional analysis of the effect of human movement on indoor airflow patterns.
        Indoor Air. 2021; 31: 587-601
        • Tang J.W.
        • Bahnfleth W.P.
        • Bluyssen P.M.
        • Buonanno G.
        • Jimenez J.L.
        • Kumitski J.
        • et al.
        Dismantling myths on the airborne transmission of severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2).
        J Hosp Infect. 2021; 110: 89-96
        • Li C.
        • Wang H.
        • Yu C.W.
        • Xie D.
        Diffusion characteristics of the industrial submicron particle under Brownian motion and turbulent diffusion.
        Indoor Built Environ. 2021; https://doi.org/10.1177/1420326X21991055
        • Wagner J.A.
        • Greeley D.G.
        • Gormley T.C.
        • Markel T.A.
        Comparison of operating room air distribution systems using the environmental quality indicator method of dynamic simulated surgical procedures.
        Am J Infect Control. 2019; 47: e1-e6
        • Agodi A.
        • Auxilia F.
        • Barchitta M.
        • Cristina M.L.
        • D'Alessandro D.
        • Mura I.
        • et al.
        Operating theatre ventilation systems and microbial air contamination in total joint replacement surgery: results of the GISIO-ISChIA study.
        J Hosp Infect. 2015; 90: 213-219
        • Birgand G.
        • Peiffer-Smadja N.
        • Fournier S.
        • Kerneis S.
        • Lescure F.X.
        • Lucet J.C.
        Assessment of air contamination by SARS-CoV-2 in hospital settings.
        JAMA NetworkOpen. 2020; 3e2033232
        • Morawska L.
        • Tang J.W.
        • Bahnfleth W.
        • Bluyssen P.M.
        • Boerstra A.
        • Buonanno G.
        • et al.
        How can airborne transmission of COVID-19 indoors be minimised?.
        Environ Int. 2020; 142: 105832
        • Ereth M.H.
        • Hess D.H.
        • Driscoll A.
        • Hernandez M.
        • Stamatatos F.
        Particle control reduces fine and ultrafine particles greater than HEPA filtration in live operating rooms and kills biologic warfare surrogate.
        Am J Infect Control. 2020; 48: 777-780
        • SecureAire, LLC
        ACTIVE Particle Control technology and USP 800 pharmaceutical compounding.
        SecureAire, Dunedin, FL2018 (Available at:) ([last accessed July 2021)
        • Raval J.S.
        • Koch E.
        • Donnenberg A.D.
        Real-time monitoring of non-viable airborne particles correlates with airborne colonies and represents an acceptable surrogate for daily assessment of cell-processing cleanroom performance.
        Cytotherapy. 2012; 14: 1144-1150
        • WHO
        Modes of transmission of virus causing COVID-19: implications for IPC precaution recommendations.
        World Health Organization, Geneva2020
        • CDC
        Interim infection prevention and control recommendations for patients with suspected or confirmed conronavirus disease 2019 (COVID-19 in healthcare settings.
        US Centers for Disease Control and Prevention, Atlanta, GA2020
        • Edwards D.A.
        • Man J.C.
        • Brand P.
        • Kastra J.P.
        • Sommerer K.
        • Stone H.A.
        • et al.
        Inhaling to mitigate exhaled bioaerosols.
        Proc Natl Acad Sci USA. 2004; 101: 17383-17388
        • Bourouiba L.
        • Dehandschoewercker E.
        • Bush J.W.M.
        Violent expiratory events: on coughing and sneezing.
        J Fluid Mech. 2014; 745: 537-563
        • Bake B.
        • Larsson P.
        • Ljungkvist G.
        • Ljungström E.
        • Olin A.C.
        Exhaled particles and small airways.
        Respir Res. 2019; 20: 8
        • van Doremalen N.
        • Bushmaker T.
        • Morris D.H.
        • Holbrook M.G.
        • Gamble A.
        • Williamson B.N.
        • et al.
        Aerosol and surface stability of SARS-CoV-2 as compared with SARS-CoV-1.
        N Engl J Med. 2020; 382: 1564-1567
        • Lindsley W.G.
        • King W.P.
        • Thewlis R.E.
        • Reynolds J.S.
        • Panday K.
        • Cao G.
        • et al.
        Dispersion and exposure to a cough-generated aerosol in a simulated medical examination room.
        J Occup Environ Hyg. 2012; 9: 681-690
        • Myatt T.A.
        • Johnston S.L.
        • Zuo Z.
        • Wand M.
        • Kebadze T.
        • Rudnick S.
        • et al.
        Detection of airborne rhinovirus and its relation to outdoor air supply in office environments.
        Am J Respir Crit Care Med. 2004; 169: 1187-1190
        • Bandaly V.
        • Joubert A.
        • Le Cann P.
        • Andres Y.
        The fate of mengovirus on fiberglass filter of air handling units.
        Food Environ Virol. 2017; 9: 464-472
        • Zeng Y
        • Manwatkar P
        • Laguerre A
        • et al.
        Evaluating a commercially available in-duct bipolar ionization device for pollutant removal and potential byproduct formation.
        Build Environ. 2021; 195
        • Zaatari M.
        • Harmon M.
        Open letter to address the use of electronic air cleaning equipment in buildings. medium.com.
        2021 (Available at:) ([last accessed August 2021])
        • Intertek
        SecureAire LLC ozone test report.
        Cortland, NY: Intertek;. 2020;
        • Ong S.W.X.
        • Tan Y.K.
        • Chia P.Y.
        • Lee T.H.
        • Ng O.T.
        • Wong M.S.Y.
        • et al.
        Air, surface environmental, and personal protective equipment contamination by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) from a symptomatic patient.
        JAMA. 2020; 323: 1610-1612
        • Wells W.F.
        Aerodynamics of droplet nuclei. Airborne contagion and air hygiene: an ecological study of droplet infections.
        Harvard University Press, Cambridge1955: 13-19
        • Brown J.H.
        • Cook K.M.
        • Ney F.G.
        • Hatch T.
        Influence of particle size upon the retention of particulate matter in the human lung.
        Am J Public Health Nations Health. 1950; 40: 450-480
        • Scheuch G.
        Breathing is enough: for the spread of influenza virus and SARS-CoV-2 by breathing only.
        J Aerosol Med Pulm Drug Deliv. 2020; 33: 230-234
        • Agency for Healthcare Research and Quality
        Healthcare-associated infections.
        Agency for Healthcare Research and Quality, Rockville, MD2018 (Available at: https://www.ahrq.gov/professionals/quality-patient-safety/patient-safety-resources/resources/hais/index.html [last accessed July 2021])
        • van Rijn C.
        • Somsen G.A.
        • Hofstra L.
        • Dahhan G.
        • Gem R.A.
        • Kooij S.
        • et al.
        Reducing aerosol transmission of SARS-CoV-2 in hospital elevators.
        Indoor Air. 2020; 30: 1065-1066
        • Bahl P.
        • Doolan C.
        • de Silva C.
        • Chughtai A.A.
        • Bourouiba L.
        • MacIntyre C.R.
        Airborne or droplet precautions for health workers treating COVID-19?.
        J Infect Dis. 2020;
        • Jones N.R.
        • Qureshi Z.U.
        • Temple R.J.
        • Larwood J.P.J.
        • Greenhalgh T.
        • Bourouiba L.
        Two metres or one: what is the evidence for physical distancing in COVID-19?.
        BMJ. 2020; 370: m3223
        • Bazant M.Z.
        • Bush J.W.M.
        A guideline to limit indoor airborne transmission of COVID-19.
        Proc Natl Acad Sci USA. 2021; 118: 17
        • Santarpia J.L.
        • Rivera D.N.
        • Herrera V.L.
        • Morwitzer M.J.
        • Creager H.M.
        • Santarpia G.W.
        • et al.
        Aerosol and surface contamination of SARS-CoV-2 observed in quarantine and isolation care.
        Sci Rep. 2020; 10: 12732
        • Leung N.H.L.
        Transmissibility and transmission of respiratory viruses.
        Nat Rev Microbiol. 2021; https://doi.org/10.1038/s41579-021-00535-6:1-18
        • Asadi S.
        • Gaaloul Ben Hnia N.
        • Barre R.S.
        • Wexler A.S.
        • Ristenpart W.D.
        • Bouvier N.M.
        Influenza A virus is transmissible via aerosolized fomites.
        Nat Commun. 2020; 11: 4062
        • Li Z.
        • Wang H.
        • Zheng W.
        • Li Z.
        • Wang H.
        • Zheng W.
        • et al.
        A tracing method of airborne bacteria transmission across built environments.
        Build Environ. 2019; 164: 106335