Control of endemic multidrug-resistant Gram-negative bacteria after removal of sinks and implementing a new water-safe policy in an intensive care unit

  • E. Shaw
    Correspondence
    Corresponding author. Address: Department of Infectious Diseases, Hospital Universitari de Bellvitge, Feixa Llarga s/n, 08907 Hospitalet de Llobregat, Barcelona, Spain. Tel.: +34 93 2607274; fax: +34 93 2607637.
    Affiliations
    Department of Infectious Diseases, Hospital Universitari de Bellvitge–IDIBELL, Barcelona, Spain

    Spanish Network for Research in Infectious Diseases, Instituto de Salud Carlos III, Madrid, Spain
    Search for articles by this author
  • L. Gavaldà
    Affiliations
    Department of Preventive Medicine, Hospital Universitari de Bellvitge–IDIBELL, Barcelona, Spain
    Search for articles by this author
  • J. Càmara
    Affiliations
    Department of Microbiology, Hospital Universitari de Bellvitge–IDIBELL, Barcelona, Spain
    Search for articles by this author
  • R. Gasull
    Affiliations
    Department of Intensive Medicine, Hospital Universitari de Bellvitge–IDIBELL, Barcelona, Spain
    Search for articles by this author
  • S. Gallego
    Affiliations
    Department of Intensive Medicine, Hospital Universitari de Bellvitge–IDIBELL, Barcelona, Spain
    Search for articles by this author
  • F. Tubau
    Affiliations
    Department of Microbiology, Hospital Universitari de Bellvitge–IDIBELL, Barcelona, Spain

    CIBER de Enfermedades Respiratorias, Instituto de Salud Carlos III, Madrid, Spain
    Search for articles by this author
  • R.M. Granada
    Affiliations
    Department of Intensive Medicine, Hospital Universitari de Bellvitge–IDIBELL, Barcelona, Spain
    Search for articles by this author
  • P. Ciercoles
    Affiliations
    Department of Infectious Diseases, Hospital Universitari de Bellvitge–IDIBELL, Barcelona, Spain
    Search for articles by this author
  • M.A. Dominguez
    Affiliations
    Department of Microbiology, Hospital Universitari de Bellvitge–IDIBELL, Barcelona, Spain

    Spanish Network for Research in Infectious Diseases, Instituto de Salud Carlos III, Madrid, Spain

    University of Barcelona, Barcelona, Spain
    Search for articles by this author
  • R. Mañez
    Affiliations
    Department of Intensive Medicine, Hospital Universitari de Bellvitge–IDIBELL, Barcelona, Spain
    Search for articles by this author
  • J. Carratalà
    Affiliations
    Department of Infectious Diseases, Hospital Universitari de Bellvitge–IDIBELL, Barcelona, Spain

    Spanish Network for Research in Infectious Diseases, Instituto de Salud Carlos III, Madrid, Spain

    University of Barcelona, Barcelona, Spain
    Search for articles by this author
  • M. Pujol
    Affiliations
    Department of Infectious Diseases, Hospital Universitari de Bellvitge–IDIBELL, Barcelona, Spain

    Spanish Network for Research in Infectious Diseases, Instituto de Salud Carlos III, Madrid, Spain
    Search for articles by this author
Published:November 02, 2017DOI:https://doi.org/10.1016/j.jhin.2017.10.025

      Summary

      Background

      Contaminated handwashing sinks have been identified as reservoirs that can facilitate colonization/infection of patients with multidrug-resistant (MDR) Gram-negative bacteria (GNB) in intensive care units (ICUs).

      Aim

      To assess the impact of removing patients' sinks and implementing other water-safe strategies on the annual rates of ICU-acquired MDR-GNB.

      Methods

      This six-year quasi-experimental study was conducted from January 2011 to December 2016. The intervention was carried out in August 2014 in two adult ICU wards with 12 rooms each. To assess the changes in annual MDR-GNB rates before and after the intervention, we used segmented regression analysis of an interrupted time-series. Crude relative risk (RR) rates were also calculated.

      Findings

      The incidence rates of MDR-GNB were 9.15 and 2.20 per 1000 patient-days in the pre- and post-intervention periods, respectively. This yielded a crude RR of acquiring MDR-GNB of 0.24 (95% confidence interval: 0.17–0.34). A significant change in level was observed between the MDR-GNB rate at the first point of the post-intervention period and the rate predicted by the pre-intervention time trend.

      Conclusion

      The implementation of a new water-safe policy, which included the removal of sinks from all patient rooms, successfully improved the control of MDR-GNB spread in an ICU with endemic infection. Our results support the contribution of sink use with the incidence of MDR-GNB in endemic environments.

      Keywords

      To read this article in full you will need to make a payment

      Purchase one-time access:

      Academic & Personal: 24 hour online accessCorporate R&D Professionals: 24 hour online access
      One-time access price info
      • For academic or personal research use, select 'Academic and Personal'
      • For corporate R&D use, select 'Corporate R&D Professionals'

      Subscribe:

      Subscribe to Journal of Hospital Infection
      Already a print subscriber? Claim online access
      Already an online subscriber? Sign in
      Institutional Access: Sign in to ScienceDirect

      References

        • European Centre for Disease Prevention and Control
        Antimicrobial resistance surveillance in Europe 2014.
        (Annual Report of the European Antimicrobial Resistance Surveillance Network (EARS-Net)) ECDC, Stockholm2015
        • Sievert D.M.
        • Ricks P.
        • Edwards J.R.
        • Schneider A.
        • Patel J.
        • Srinivasan A.
        • et al.
        Antimicrobial-resistant pathogens associated with healthcare-associated infections: summary of data reported to the National Healthcare Safety Network at the Centers for Disease Control and Prevention, 2009–2010.
        Infect Control Hosp Epidemiol. 2013; 34: 1-14
        • Centers for Disease Control and Prevention (CDC)
        Vital signs: carbapenem-resistant Enterobacteriaceae.
        Morb Mortal Wkly Rep. 2013; 62: 165-170
        • Cubero M.
        • Cuervo G.
        • Domínguez M.A.
        • Tubau F.
        • Martí S.
        • Sevillano E.
        • et al.
        Carbapenem-resistant and carbapenem-susceptible isogenic isolates of Klebsiella pneumoniae ST101 causing infection in a tertiary hospital.
        BMC Microbiol. 2015; 15: 177
        • Pagani L.
        • Perilli M.
        • Migliavacca R.
        • Luzzaro F.
        • Amicosante G.
        Extended-spectrum TEM- and SHV-type beta-lactamase-producing Klebsiella pneumoniae strains causing outbreaks in intensive care units in Italy.
        Eur J Clin Microbiol Infect Dis. 2000; 19: 765-772
        • Kohlenberg A.
        • Weitzel-Kage D.
        • van der Linden P.
        • Sohr D.
        • Vögeler S.
        • Kola A.
        • et al.
        Outbreak of carbapenem-resistant Pseudomonas aeruginosa infection in a surgical intensive care unit.
        J Hosp Infect. 2010; 74: 350-357
        • Suarez C.
        • Peña C.
        • Arch O.
        • Dominguez M.A.
        • Tubau F.
        • Juan C.
        • et al.
        A large sustained endemic outbreak of multiresistant Pseudomonas aeruginosa: a new epidemiological scenario for nosocomial acquisition.
        BMC Infect Dis. 2011; 11: 272
        • Gavaldà L.
        • Pequeño S.
        • Soriano A.
        • Dominguez M.A.
        Environmental contamination by multidrug-resistant microorganisms after daily cleaning.
        Am J Infect Control. 2015; 43: 776-778
        • Lowe C.
        • Willey B.
        • O’Shaughnessy A.
        • Lee W.
        • Lum M.
        • Pike K.
        • et al.
        Outbreak of extended-spectrum β-lactamase-producing Klebsiella oxytoca infections associated with contaminated handwashing sinks.
        Emerg Infect Dis. 2012; 18: 1242-1247
        • Kotsanas D.
        • Wijesooriya W.R.
        • Korman T.M.
        • Gillespie E.E.
        • Wright L.
        • Snook K.
        • et al.
        “Down the drain”: carbapenem-resistant bacteria in intensive care unit patients and handwashing sinks.
        Med J Aust. 2013; 198: 267-269
        • Tacconelli E.
        • Cataldo M.A.
        • Dancer S.J.
        • De Angelis G.
        • Falcone M.
        • Frank U.
        • et al.
        ESCMID guidelines for the management of the infection control measures to reduce transmission of multidrug-resistant Gram-negative bacteria in hospitalized patients.
        Clin Microbiol Infect. 2014; 20: 1-55
        • Knoester M.
        • de Boer M.G.
        • Maarleveld J.J.
        • Claas E.C.
        • Bernards A.T.
        • de Jonge E.
        • et al.
        An integrated approach to control a prolonged outbreak of multidrug-resistant Pseudomonas aeruginosa in an intensive care unit.
        Clin Microbiol Infect. 2014; 20: O207-O215
        • Langer A.J.
        • Lafaro P.
        • Genese C.A.
        • McDonough P.
        • Nahass R.
        • Robertson C.
        Using active microbiologic surveillance and enhanced infection control measures to control an outbreak of health care-associated extended-spectrum beta-lactamase-producing Klebsiella pneumoniae infections – New Jersey, 2007.
        Am J Infect Control. 2009; 37: 73-75
        • Hota S.
        • Hirji Z.
        • Stockton K.
        • Lemieux C.
        • Dedier H.
        • Wolfaardt G.
        • et al.
        Outbreak of multidrug-resistant Pseudomonas aeruginosa colonization and infection secondary to imperfect intensive care unit room design.
        Infect Control Hosp Epidemiol. 2009; 30: 25-33
        • Vergara-López S.
        • Domínguez M.C.
        • Conejo M.C.
        • Pascual Á.
        • Rodríguez-Baño J.
        Wastewater drainage system as an occult reservoir in a protracted clonal outbreak due to metallo-β-lactamase-producing Klebsiella oxytoca.
        Clin Microbiol Infect. 2013; 19: E490-E498
        • Roux D.
        • Aubier B.
        • Cochard H.
        • Quentin R.
        • van der Mee-Marquet N.
        Contaminated sinks in intensive care units: an underestimated source of extended-spectrum beta-lactamase-producing Enterobacteriaceae in the patient environment.
        J Hosp Infect. 2013; 85: 106-111
        • Wolf I.
        • Bergervoet P.W.
        • Sebens F.W.
        • van den Oever H.L.
        • Savelkoul P.H.
        • van der Zwet W.C.
        The sink as a correctable source of extended-spectrum β-lactamase contamination for patients in the intensive care unit.
        J Hosp Infect. 2014; 87: 126-130
        • Bédard E.
        • Laferrière C.
        • Charron D.
        • Lalancette C.
        • Renaud C.
        • Desmarais N.
        • et al.
        Post-outbreak investigation of Pseudomonas aeruginosa tap contamination by quantitative polymerase chain reaction and environmental factors affecting positivity.
        Infect Control Hosp Epidemiol. 2015; 36: 1337-1343
        • Gavaldà L.
        • Soriano A.M.
        • Cámara J.
        • Gasull R.
        • Arch O.
        • Ferrer M.
        • et al.
        Control of endemic extensively drug-resistant Acinetobacter baumannii with a cohorting policy and cleaning procedures based on the 1 room, 1 wipe approach.
        Am J Infect Control. 2016; 44: 520-524
        • Corbella X.
        • Pujol M.
        • Ayats J.
        • Sendra M.
        • Ardanuy C.
        • Domínguez M.A.
        • et al.
        Relevance of digestive tract colonization in the epidemiology of nosocomial infections due to multiresistant Acinetobacter baumannii.
        Clin Infect Dis. 1996; 23: 329-334
        • European Committee on Antimicrobial Susceptibility Testing
        Breakpoint tables for interpretation of MICs and zone diameters.
        2017 (Version 7.1. Available at:) ([last accessed June 2017])
        • Ramsay C.R.
        • Matowe L.
        • Grilli R.
        • Grimshaw J.M.
        • Thomas R.E.
        Interrupted time series designs in health technology assessment: lessons from two systematic reviews of behavior change strategies.
        Int J Technol Assess Health Care. 2003; 19: 613-623
        • Ayliffe G.A.
        • Babb J.R.
        • Collins B.J.
        • Lowbury E.J.
        • Newsom S.W.
        Pseudomonas aeruginosa in hospital sinks.
        Lancet. 1974; 2: 578-581
        • Reuter S.
        • Sigge A.
        • Wiedeck H.
        • Trautmann M.
        Analysis of transmission pathways of Pseudomonas aeruginosa between patients and tap water outlets.
        Crit Care Med. 2002; 30: 2222-2228
        • Trautmann M.
        • Lepper P.M.
        • Haller M.
        Ecology of Pseudomonas aeruginosa in the intensive care unit and the evolving role of water outlets as a reservoir of the organism.
        Am J Infect Control. 2005; 33: S41-S49
        • Rogues A.M.
        • Boulestreau H.
        • Lashéras A.
        • Boyer A.
        • Gruson D.
        • Merle C.
        • et al.
        Contribution of tap water to patient colonisation with Pseudomonas aeruginosa in a medical intensive care unit.
        J Hosp Infect. 2007; 67: 72-78
        • Kac G.
        • Podglajen I.
        • Vaupré S.
        • Colardelle N.
        • Buu-Hof A.
        • Gutmann L.
        Molecular epidemiology of extended-spectrum beta-lactamase-producing Enterobacteriaceae isolated from environmental and clinical specimens in a cardiac surgery intensive care unit.
        Infect Control Hosp Epidemiol. 2004; 25: 852-855
        • Salm F.
        • Deja M.
        • Gastmeier P.
        • Kola A.
        • Hansen S.
        • Behnke M.
        • et al.
        Prolonged outbreak of clonal MDR Pseudomonas aeruginosa on an intensive care unit: contaminated sinks and contamination of ultra-filtrate bags as possible route of transmission?.
        Antimicrob Resist Infect Control. 2016; 5: 53
        • Kizny Gordon A.E.
        • Mathers A.J.
        • Cheong E.Y.
        • Gottlieb T.
        • Kotay S.
        • Walker A.S.
        • et al.
        Is the hospital water environment a reservoir for carbapenem-resistant organisms causing hospital-acquired infections? A systematic review of the literature.
        Clin Infect Dis. 2017; 64: 1435-1444
        • Stjärne Aspelund A.
        • Sjöström K.
        • Olsson Liljequist B.
        • Mörgelin M.
        • Melander E.
        • Påhlman L.I.
        Acetic acid as a decontamination method for sink drains in a nosocomial outbreak of metallo-β-lactamase-producing Pseudomonas aeruginosa.
        J Hosp Infect. 2016; 94: 13-20
        • Hopman J.
        • Tostmann A.
        • Wertheim H.
        • Bos M.
        • Kolwijck E.
        • Akkermans R.
        • et al.
        Reduced rate of intensive care unit acquired Gram-negative bacilli after removal of sinks and introduction of water-free patient care.
        Antimicrob Resist Infect Control. 2017; 6: 59

      Linked Article

      • Response to Shaw et al.
        Journal of Hospital InfectionVol. 100Issue 1
        • Preview
          We read with interest the work of Shaw et al. which aimed ‘to assess the impact of removing patients’ sinks and implementing other water-safe strategies on the annual rates of ICU [intensive care unit]-acquired MDR-GNB [multi-drug-resistant Gram-negative bacteria]’ [1]. The authors used segmented regression analysis of an interrupted time-series (ITS) and estimated the relative risk (RR) of their intervention on water. We commend the authors for performing this interesting study. However, we have several statistical suggestions and queries that we would like to communicate with the authors.
        • Full-Text
        • PDF