Is it really clean? An evaluation of the efficacy of four methods for determining hospital cleanliness

  • O. Sherlock
    Correspondence
    Corresponding author. Address: Department of Clinical Microbiology, RCSI Education and Research Centre, Beaumont Hospital, PO Box 9063, Beaumont Road, Dublin 9, Ireland. Tel.: +353 1 8093728; fax: +353 1 8093709.
    Affiliations
    Department of Clinical Microbiology, Education and Research Centre, Royal College of Surgeons in Ireland, Dublin, Ireland
    Search for articles by this author
  • N. O'Connell
    Affiliations
    Department of Clinical Microbiology, Education and Research Centre, Royal College of Surgeons in Ireland, Dublin, Ireland
    Search for articles by this author
  • E. Creamer
    Affiliations
    Department of Clinical Microbiology, Education and Research Centre, Royal College of Surgeons in Ireland, Dublin, Ireland
    Search for articles by this author
  • H. Humphreys
    Affiliations
    Department of Clinical Microbiology, Education and Research Centre, Royal College of Surgeons in Ireland, Dublin, Ireland

    Department of Microbiology, Beaumont Hospital, Dublin, Ireland
    Search for articles by this author

      Summary

      An important component of effective cleaning in hospitals involves monitoring the efficacy of the methods used. Generally the recommended tool for monitoring cleaning efficacy is visual assessments. In this study four methods to determine cleaning efficacy of hospital surfaces were compared, namely visual assessment, chemical (ATP) and microbiological methods, i.e. aerobic colony count (ACC) and the presence of meticillin-resistant Staphylococcus aureus. Respectively, 93.3%, 71.5%, 92.1% and 95.0% of visual, ATP, ACC and MRSA assessments were considered acceptable or ‘clean’ according to each test standard. Visual assessment alone did not always provide a meaningful measure of surface cleanliness or cleaning efficacy. The average ATP value from 120 swabs before cleaning was 612 relative light units (RLU) (range: 72–2575) and 375 RLU after cleaning (range: 106–1071); the accepted standard is 500 RLU. In a hospital setting with low microbiological counts, the use of chemical tests such as ATP may provide additional information of cleaning efficacy and ATP trends allow identification of environmental surfaces that require additional cleaning or cleaning schedule amendments.

      Keywords

      To read this article in full you will need to make a payment

      Subscribe:

      Subscribe to Journal of Hospital Infection
      Already a print subscriber? Claim online access
      Already an online subscriber? Sign in
      Institutional Access: Sign in to ScienceDirect

      References

        • Hota B.
        Contamination, disinfection, and cross-colonisation? Are hospital surfaces reservoirs for nosocomial infection?.
        Clin Infect Dis. 2004; 39: 1182-1189
        • Dancer S.J.
        Importance of the environment in meticillin-resistant Staphylococcus aureus acquisition: the case for hospital cleaning.
        Lancet Infect Dis. 2008; 8: 101-113
        • Al-Hamad A.
        • Maxwell S.
        How clean is clean? Proposed methods for hospital cleaning assessment.
        J Hosp Infect. 2008; 1: 1-7
        • Cooper R.A.
        • Griffith C.J.
        • Malik R.E.
        • Obee P.
        • Looker N.
        Monitoring the effectiveness of cleaning in four British hospitals.
        Am J Infect Control. 2007; 35: 338-341
        • Dancer S.J.
        How do we assess hospital cleaning? A proposal for microbiological standards for surface hygiene in hospitals.
        J Hosp Infect. 2004; 56: 10-15
        • Chittock R.S.
        • Hawronskyi J.M.
        • Holah J.
        • Wharton C.W.
        Kinetic aspects of ATP amplification reactions.
        Anal Biochem. 1998; 255: 120-126
        • Goodman E.R.
        • Platt R.
        • Bass R.
        • Onderdonk A.B.
        • Yokoe D.S.
        • Huang S.S.
        Impact of an environmental cleaning intervention on the presence of meticillin-resistant Staphylococcus aureus and vancomycin-resistant enterococci on surfaces in intensive care unit rooms.
        Infect Control Hosp Epidemiol. 2008; 7: 593-599
        • Malik R.E.
        • Cooper R.A.
        • Griffith C.J.
        Use of audit tools to evaluate the efficacy of cleaning systems in hospitals.
        Am J Infect Control. 2003; 31: 181-187
        • Griffith C.J.
        • Cooper R.A.
        • Gilmore J.
        • Davies C.
        • Lewis M.
        An evaluation of hospital cleaning regimes and standards.
        J Hosp Infect. 2000; 45: 19-28
        • Griffith C.J.
        • Obee P.
        • Cooper R.A.
        • Burton N.F.
        • Lewis M.
        The effectiveness of existing and modified cleaning regimens in a Welsh hospital.
        J Hosp Infect. 2007; 66: 352-359
        • Dancer S.J.
        • White L.
        • Robertson C.
        Monitoring environmental cleanliness on two surgical wards.
        Int J Environ Health Res. 2008; 18: 357-364
        • Lewis T.
        • Griffith C.
        • Gallo M.
        • Weinbren M.
        A modified ATP benchmark for evaluating the cleaning of some hospital environmental surfaces.
        J Hosp Infect. 2008; 2: 156-163
        • White L.F.
        • Dancer S.J.
        • Robertson C.
        A microbiological evaluation of hospital cleaning methods.
        Int J Environ Health Res. 2007; 17: 285-295
        • Boyce J.M.
        Environmental contamination makes an important contribution to hospital infection.
        J Hosp Infect. 2007; 65: 50-54
        • Larson E.L.
        • Aiello A.E.
        • Gomez-Duarte C.
        • et al.
        Bioluminescence ATP monitoring as a surrogate marker for microbial load on hands and surfaces in the home.
        Food Microbiol. 2003; 20: 735-739
        • Lewis T.
        • Gallo M.
        • Weinbren M.
        • Griffith C.J.
        An assessment of the effectiveness of modified hospital cleaning protocols using visual, ATP bioluminescence, and microbiological analysis.
        J Hosp Infect. 2006; 64: 55-56
        • Carling P.C.
        • Briggs J.
        • Hylander D.
        • Perkins J.
        An evaluation of patient area cleaning in 3 hospitals using novel targeting methodology.